Call 08048963913 87% Response Rate

our range

Combined Louver

Offering you a complete choice of products which include gravity intake back draft damper combined louver, low leak adjustable damper combined louver and gravity exhaust back draft damper combined louver.
Gravity Intake Back Draft Damper Combined Louver

Gravity Intake Back Draft Damper Combined Louver

Rs 11,000  / Square MeterGet Best Price

Product Brochure

Usage/ApplicationBackdraft
MaterialAluminum
BrandGlenstorms
Model NumberG-AL-CG-I
Pressure4 in. w.g. - differential pressure
Velocity2000 fpm free are velocity
Temperature122 degree F
Water Penetration1060 fpm free are velocity
Bird Screen Size3/4 x 0.051 inch
Minimum Size12x12 inch (WxH)
Maximum Size48x96 inch (WxH)
Free Area40%
Gravity Intake Back Draft Damper Combined Louver type of louver has a feature of stationary front louver that provides added weather protection and secondary gravity intake backdraft damper.

Application and Design: Features a stationary front louver that provides added weather protection and secondary gravity intake backdraft damper. Design incorporates extruded aluminium 4.5 inch deep drainable head member with both side flange, primary stationary horizontal louvers to channel water to the jambs which guides the water through vertical down-spouts for escape at the sill, and secondary gravity louver blades. These louvers are ideal for situation where airflow is required in one direction with protection against water penetration. 

View Complete details

get quote request a call back
Low Leak Adjustable Damper Combined Louver

Low Leak Adjustable Damper Combined Louver

Rs 10,500  / Square MeterGet Best Price

Product Brochure

Louver TypeCombination Louver
Usage/ApplicationBackdraft
MaterialAluminium
BrandGlenstorms
Model NumberG-AL-CD
Pressure4 in. w.g. - differential pressure
Velocity2000 fpm free are velocity
Temperature122 degree F
Water Penetration1060 fpm free are velocity
Bird Screen Size3/4 x 0.051 inch
Free Area48%
Minimum Size12x12 inch (WxH)
Maximum Size48x96 inch (WxH)
Low Leak Adjustable Damper Combined Louver type of louver has a feature of front stationary louver thats provides added weather protection and secondary operable damper.

Application and Design: Features a stationary front louver that provides added weather protection and secondary operable damper. Design incorporates extruded aluminium 4.5 inch deep drainable head member with both side flange, primary stationary horizontal louvers to channel water to the jambs which guide the water through vertical down-spouts for escape at the sill, and secondary gear driven blades with EPDM blade edge seal. These louvers are ideal for situations where airflow is not required at all times and blade closure is desired to restrict weather infiltration. Also available with electric actuator for automatic control. 

View Complete details

get quote request a call back
Gravity Exhaust Back Draft Damper Combined Louver

Gravity Exhaust Back Draft Damper Combined Louver

Rs 11,000  / Square MeterGet Best Price

Product Brochure

Louver TypeCombination Louver
Usage/ApplicationBackdraft
MaterialAluminium
BrandGlenstorms
Model NumberG-AL-CG-E
Pressure4 in. w.g. - differential pressure
Velocity2000 fpm free are velocity
Temperature122 degree F
Free Area40%
Water Penetration1060 fpm free are velocity
Bird Screen Size3/4 x 0.051 inch
Minimum Size12x12 inch (WxH)
Maximum Size48x96 inch (WxH)
Gravity Exhaust Back Draft Damper Combined Louver type of louver has a feature of stationary front louver that provides added weather protection and secondary gravity exhaust backdraft damper.

Application and Design: Features a stationary front louver that provides added weather protection and secondary gravity exhaust backdraft damper. Design incorporates extruded aluminium 4.5 inch deep drainabte head member with both side flange, primary stationary horizontal louvers to channel water to the jambs which guides the water through vertical down-spouts for escape at the sill, and secondary gravity louver blades. These louvers are ideal for situation where airflow is required in one direction with protection against water penetration. 

View Complete details

get quote request a call back

EXPLORE MORE CATEGORIES